15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout

Breaking Capacity: High
Type: Current Fuse
Usage: High Voltage
Shape: Circle
Fusing Speed: K, T, H
Fusing Device: Fuse Link
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (26)

Basic Info.

Model NO.
fsc-12
Standard
IEC60282-2, ANSI C37.41, ANSI C37.42
Sample
Provided
OEM Service
Provided
Fuse Base Material
Porcelain
Function
Over-Current Protection
Transport Package
Carton, Pallet
Specification
66*36*16
Trademark
FUERTE
Origin
China
HS Code
85351000
Production Capacity
5000000

Product Description


Conditions of Use
Ambient temperature: Not higher than +40 º C, not less than -30 º C
Altitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)
Power frequency: 50 ± 2Hz
Earthquake intensity: 7 degrees below
Maximum wind speed: 35m/s   

 

Type

Rated

voltage

(kV)

Rated

current

  (A)

Breaking

current

   (A)

Impulse

voltage

 (BIL) 

Power-frequency

withstand voltage

       (kV) 

Leakage

distance

   (mm) 

 Weight

  (kg)

FSC-12     15-27KV    100    10000   125      45    320    8.5
FSC-12     15-27KV    200    12000   125      45    320    8.5
 

General
Drop-out fuse and pull the load drop-out fuse is outdoor high-voltage protection of electrical. It is installed in high-voltage side of the distribution transformer or the Support Link of the distribution line as Transformers and lines short circuit, overload protection, and open, co-load current. Drop-out fuse is made by the insulating bracket and fuse tubes, static contact is installed at both ends of the insulation bracket, Moving contact installed on both ends of fuse tube, Fuse tube is composed by inner arc tube and outer phenolic paper tube or epoxy glass cloth tube. Pull load drop-out fuse can enhance flexibility auxiliary contacts and arc chute for open, co-load current. 
When drop-out fuse in the normal operation, the fuse tube with fuse tension to form the closed position. When the system fails, the fault current blown fuse quickly, And form of arc, arc tube by the electric arc burning, Decompose large amounts of gas, formed a high pressure in the tube, and formed vertical wind along the pipeline, The arc was quickly stretch and elongated. After fuse blows, the moving contact lose tension and turned out, locking mechanism, release fuse tube, fuse tube drop, formed breaking Position. When pull the load, use insulating rod to pull the moving contact. At this point, the moving and the static contact is still contact. Continued pull the contact with the insulating rod, the auxiliary contacts are separated. The arc appear between the auxiliary contacts, and was stretch in the hood slit, the arc cover has gas, when the current is 0, the arc goes out. 

Use and Standards
This product is used in 10 ~ 35KV distribution lines branching lines and distribution transformers primary side, For overload and short circuit protection Separation and Combination the rated load current. 
The product model by JB/T8321-1996Method of type AC high-voltage fuses prepared. Product parameters made by GB15166.3-1994 high voltage fuses Expulsion fusesstandards. The standards are not clearly defined the important parameters and configuration, According to JB/DQ2139-198610 ~ 35KV outdoor high voltage drop fuse interim technology requires correction. 
15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
110000000 RMB
Plant Area
>2000 square meters