Type: | Lightning Arrester |
---|---|
Structure: | Zinc Oxide Arrester |
Installation: | NEMA Bracket Mounting on Pole |
Application: | Substation |
Size: | Small |
Operation Voltage: | High Voltage |
Customization: |
---|
Suppliers with verified business licenses
The zinc oxide surge arrester is the most advanced over-voltage protector in the world. Due to make the resistor disc of core component mainly adopt zinc oxide arrester. Compared with the conventional siliconcarbide arrester, this prescription of the product improves greatly the volt-ampere characteristics of the resistor disc and increase through-current capability at over-voltage so as to bring a rad local-changes for the characteristics of the arresters.
Electrical characteristics | Specification | Unit | |
Rated voltage of Surge arrreser | 12 | kV | |
Nominal discharge current | 5 | 10 | kA |
Rated frequency | 50 | Hz | |
Maximum continuous operating voltage | 10.2 | kV | |
Steep current impulse residual voltage | 42.2 | kV(Crest) | |
Lightning Impulse residual voltage | 36 | kV(Crest) | |
Switching Impulse residual voltage | 31.7 | kV(Crest) | |
Long duration current impulse withstand voltage |
150 | 250 | A |
High current impulses | 65 | 100 | kA (Crest) |
Rated Short-circuit current | 20 / 12 / 6 / 0.6 ± 0.2 | kA | |
Class of Surge arrester | Class 1 or Class 2 | ||
Application | Distribution type | ||
With or without gap | Gapless | ||
Designation of arrester | Design B | ||
Spare parts | |||
NEMA A or B mounting bracket | with/without | ||
Disconnector | with/without | ||
Earth lead | with/without | ||
Bird guard cap | with/without | ||
Line clamp | with/without | ||
Upper terminal (incoming line) bolt size | M12 | ||
Lower termina (outgoing line) bolt size | M10 | ||
Material | |||
Upper terminal | Stainless steel 304 | ||
Housing | Polymer type | ||
Color of housing | Dark grey / light grey | ||
Varistor | High quality zinc oxide varistor | ||
Size of Varistor | 35mm / 38mm /40mm / 42mm | ||
Package | |||
Qty/package | 3 | pc/carton | |
Service conditions | |||
Environment maximum temperature | 40 | ºC | |
Pollution level | Heavy | ||
Altitude | ≤1000 | Meter | |
Standard | IEC60099-4:2014 |
1.The ambient temperature: -40°C ~+40°C
2.The altitude above sea level :not exceed 1000-2000m(the altiplano area should be indicated when order)
3.Earthquake intensity: not higher than 7 degrees;
4.Maximum wind velocity :lower than 35m/s.
5.The filthy area should be given clear indication.